XM-1000 5-Gas Analyzer

Portable and Economical Exhaust Gas Analyzer (For Audit)

pdf logo

DyneSystems XM-1000 5-Gas Exhaust Analyzer is Portable and EconomicalDyneSystems' XM-1000 Exhaust Measurement System provides a portable, low cost tool for continuous analysis of engine exhaust gas components (HC, CO, CO2, NO, O2).

Free Up Your Expensive Certified Emissions Bench

This emissions test system provides the features of a raw-gas emissions bench at a fraction of the cost of full scale, certified equipment, and is packaged in a portable enclosure for mobility to move between different test cells with ease. Save time and money by using it to “pre-certify” engines before scheduling them for your certified bench.

Utilizes Andros 6600® 5-Gas Analyzer

The ANDROS 6600 analyzer is used extensively in emissions-checking stations. It is usually packaged as a hand-held, non-continuous sampling system.

The XM-1000 exhaust gas analyzer wraps a robust, continuous sampling, conditioning and calibration system around an ANDROS 6600 5-gas analyzer. The analyzer is highly repeatable, utilizing NDIR and Electro-Chem sampling methods, making it an excellent diagnostic tool when packaged and integrated in a solid system.

A heated pre-filter, heated hose, and heated filter with temperature controls are offered as an option for sample gas conditioning.

Touch-screen Interface

The XM-1000 includes a touch-screen interface for manual operation, calibration and operator data viewing, and offers a computer port for communications and data acquisition that can be connected to DyneSystems' Cell Assistant for Windows data acquisition software.

Screen image showing XM-1000 interfacing with Cell AssistantInterfacing with Cell Assistant
XM-1000 Leak Check screenLeak Check
XM-1000 Maintenance Information screenMaintenance Information
XM-1000 Gas Calibration screenManage Calibration of Gases

Features

The XM 1000 provides many of the features of high-end gas analyzers but at a small fraction of their cost.

  • Heated Pre-Filter to remove large particulates from the sample
  • Heated sample line to keep the sample temperature above the dew point
  • Heated filter to remove smaller particulates from the sample
  • Two-stage chiller to remove moisture from the sample
  • HC Hangup Test and Leak Check
  • Calibration (Zero and Span)
  • Zero calibration with “Zero” calibration gas or with ambient air
  • Purge
  • Simplified Maintenance - filters are easily replaced in the field
  • Portability - can easily be moved from one test cell to another (58″h x 21″w x 26″d)
  • Wall mount enclosure option (48″h x 36″w x 12″d)
GAS MEASUREMENT SPECIFICATIONS
Gas Range Accuracy Response Time
HC (n-Hexane) 0 to 2,000 ppm ±4ppm or ±3% of reading
≤ 2 sec
2,001 to 15,000 ppm ±5% of reading
15,001 ppm to 30,000 ppm ±8% of reading
HC (Propane) 0 to 4,000 ppm ±8ppm or ±3% of reading ≤ 2 sec
4,001 to 30,000 ppm ±5% of reading
30,001 to 60,000 ppm ±8% of reading
CO 0.00 to 10.00% ±0.02% or ±3% of reading ≤ 2 sec
10.01 to 15.00% ±5% of reading
CO2 0.00 to 16.00% ±0.3% or ±3% of reading ≤ 2 sec
16.01 to 20.00% ±5% of reading
NOx 0 to 4,000 ppm ±25 ppm or ±4% of reading ≤ 5 sec
4,001 to 5,000 ppm ±5% of reading
O2 0.00 to 25.00% ±0.1% abs. or ±3% of reading ≤ 10 sec
rise time
(0.10% to 20.9%)
≤ 30 sec
fall time
(20.9% to 0.10%)